What Size Air Compressor Does a Rock Drill Need?

A rock drill is only as good as the air behind it. Undersize the compressor and the drill loses impact energy, the penetration rate falls, and the operator blames the machine. Oversize it and you have paid for a bigger unit and you burn more fuel every hour for air you never use. This guide gives the published air consumption of each Set Makina rock drill, shows how to add them up for a working site, and covers the losses that catch buyers out.

Key takeaways

  • Size from the drill, not from the compressor catalogue. The number you need is air consumption in m³/min at the drill’s working pressure of 6 bar.
  • Published consumption at 6 bar: Y20 1.32 m³/min, Y24 3.00 m³/min, YT24 3.60 m³/min, YT28 4.80 m³/min, SETJET 2.1 DTH hammer 2.10 m³/min.
  • Add the drills that will run at the same time, then add a planning allowance of 20–30% for hose losses, wear and simultaneity.
  • Pressure is measured at the drill, not at the compressor outlet. Keep the drill within 100 m of the compressor, or fit an air receiver.
  • At altitude a compressor delivers less than its rated output. Ask the compressor manufacturer for the derating table for your site elevation.

1. The only number that matters at the start

Compressor selection in a quarry usually starts at the wrong end. Someone looks at compressors, picks a familiar size, and then finds out how many drills it will actually run. The order should be the other way round: decide what you are drilling and with which machines, total the air those machines consume, and let that total choose the compressor.

For pneumatic rock drills that figure is air consumption, expressed in cubic metres per minute at a stated working pressure. Every Set Makina rock drill is rated at a working pressure of 6 bar, which is about 87 psi. Two drills with similar weight can have very different appetites for air, so the weight of the machine tells you nothing useful about the compressor.

2. Published air consumption of the Set Makina range

These are the figures published on each product page, measured at 6 bar. The cubic feet per minute column is a conversion of the same figure, at 1 m³/min = 35.31 cfm.

ModelTypeAir at 6 barEquivalentImpact energyWeight
Y20Hand-held1.32 m³/min47 cfm~39 N·m18 kg
Y24Hand-held3.00 m³/min106 cfm~55 N·m24 kg
YT24Air-leg3.60 m³/min127 cfm~75 N·m24 kg
YT28Air-leg4.80 m³/min170 cfm~84 N·m26 kg
SETJET 2.1DTH hammer2.10 m³/min74 cfm——

Two things in that table are worth a second look. The Y20 runs on a third of the air the YT28 needs, which is why it remains the sensible machine for scattered secondary work and for sites where compressor capacity is the binding constraint. And the SETJET 2.1 down-the-hole hammer drills a much larger hole than a hand-held drill while consuming less air than a Y24, because a DTH hammer puts the piston at the bottom of the hole instead of transmitting energy down a drill string.

All four top-hammer drills in the table cover the same 32–45 mm hole diameter range and use a 22 × 108 mm shank, so the choice between them is about impact energy, drilling direction and available air rather than hole size.

3. Adding up a site

Total only the drills that will be running at the same moment. A quarry that owns six drills but works two faces with two drills each needs air for four, not six. Once you have the simultaneous total, add a planning allowance.

We suggest 20–30% above the arithmetic total. That allowance is not padding. It covers pressure drop along the hose, the gradual rise in consumption as a drill wears, the moment when an operator opens a blow valve to clear a hole, and the fact that compressor output falls as ambient temperature and altitude rise. Published drill consumption is a figure for a drill in good condition at 6 bar at the inlet; a working site is never exactly that.

SiteSimultaneous drillsArithmetic totalWith 30% allowancePractical compressor
Single drill, dimension stone1 × Y243.00 m³/min3.9 m³/min4 m³/min class
Small quarry, one face3 × Y249.00 m³/min11.7 m³/min12 m³/min class
Quarry plus development3 × Y24 + 1 × YT2813.80 m³/min17.9 m³/min18 m³/min class
Underground drive2 × YT289.60 m³/min12.5 m³/min12–13 m³/min class
Blasthole drilling, DTH1 × SETJET 2.12.10 m³/min2.7 m³/min3 m³/min class at 6 bar

The allowance is a planning figure from our own application experience, not a published specification. If you intend to run a compressor permanently at its ceiling, use the upper end of the range.

4. Four losses that undo a correct calculation

Hose length and internal diameter

Pressure is what the drill feels at its own inlet, not what the gauge on the compressor says. Every metre of hose, every coupling and every bend costs pressure, and a hose that is too narrow costs far more than its length suggests. The Y24 and YT28 take a 3/4″ air inlet. Our guidance is to keep the drill within 100 m of the compressor; beyond that distance, fit a TIGER Air Receiver near the working face so the drill draws from a stable local volume instead of down a long pipe. Use the correct pneumatic hose and fittings rather than whatever is on the yard.

Leaks

A neglected air line commonly wastes 20 to 30% of what the compressor produces, which is enough to turn a correctly sized installation into an undersized one without anything on the site changing. This is the cheapest capacity you will ever recover, and we covered how to find and cost it in compressed air leaks in quarries and mines.

Altitude

A compressor rated at sea level delivers less free air as elevation rises, because it is drawing thinner air. Quarries at 1,500 m or higher are affected materially. There is no universal correction to apply here: ask the compressor manufacturer for the derating table for your model and your site elevation, and size on the derated figure, not the nameplate.

Lubrication

Air is a consumable and so is oil. Every drill in the range ships with the FY200B external line oiler, which lubricates the percussion mechanism continuously. A drill running dry loses impact energy and consumes more air to do less work, which shows up as a compressor that suddenly seems too small.

5. Worked example: a small granite quarry

Take an operation opening a granite face with three Y24 hand-held drills for vertical holes and one YT28 on an air-leg for horizontal work, all four running through the shift.

Arithmetic total: (3 × 3.00) + 4.80 = 13.80 m³/min. Add 30%: 17.9 m³/min. Select an 18 m³/min class compressor delivering at least 7 bar at the outlet so that 6 bar still reaches the drill after hose losses. If the face is more than 100 m from the compressor, add an air receiver at the face. If the quarry sits at 1,800 m, apply the manufacturer’s altitude derating before selecting, which in practice moves you to the next size up.

If that same operation later swaps the three hand-held drills for DTH blasthole drilling, the air arithmetic changes completely and usually in your favour per cubic metre of rock. Which method suits a granite deposit is a separate decision, and we set out the cost comparison in drilling or cutting for granite extraction and the full fleet in the granite quarry equipment list.

6. Pressure and volume are not interchangeable

Two specifications govern a compressor: the volume of free air it delivers, in m³/min, and the pressure it holds while delivering it, in bar. A rock drill needs both. More pressure than 6 bar at the drill does not buy a proportional gain in penetration and it accelerates wear on the percussion mechanism; less pressure costs impact energy immediately. More volume than the drills consume does nothing at all except raise fuel consumption.

So the specification to hand a compressor supplier is a pair, not a single figure: the derated volume you calculated, at a pressure that still leaves 6 bar at the drill inlet after the hose. A compressor advertised at 6 bar is the wrong choice for a drill that needs 6 bar at the far end of 80 m of hose.

The rule in one line. Add the published m³/min of every drill running at once, add 20–30%, derate for altitude, and buy a compressor that delivers that volume at a pressure high enough to leave 6 bar at the drill.

7. If the compressor is already on site

Many buyers come to us with the compressor fixed and the drills still open. The same table answers that question backwards. Divide the available derated output by 1.3 to get the air you can actually commit, then fill it with drills. An operator with 10 m³/min available can run three Y24 drills comfortably, or two YT28 drills, or a mixed pair of YT24 and Y24 with capacity left for a blow line. Tell us the compressor you have and what you are drilling, and we will tell you which combination fits it.

What size compressor do I need for one Y24 rock drill?

The Y24 consumes 3.00 m³/min of air at 6 bar. With a planning allowance of 20–30% for hose losses and wear, a compressor in the 4 m³/min class is the practical choice for a single Y24, delivering at least 7 bar at the outlet so 6 bar reaches the drill.

How much air does a YT28 air-leg rock drill use?

The YT28 consumes 4.80 m³/min at a working pressure of 6 bar, through a 3/4″ air inlet. Two YT28 drills running together need about 12 to 13 m³/min once the allowance for losses is included.

How do I convert m³/min to cfm for a rock drill?

Multiply by 35.31. A Y24 at 3.00 m³/min is about 106 cfm, and a YT28 at 4.80 m³/min is about 170 cfm. The working pressure of 6 bar is about 87 psi.

How far can a rock drill be from the compressor?

Keep the drill within 100 m of the compressor. Beyond that, pressure drop along the hose starts to cost impact energy, and an air receiver should be placed near the working face so the drill draws from a stable local volume.

Does altitude change the compressor size I need?

Yes. A compressor delivers less free air as site elevation rises, so a unit rated at sea level may fall short at 1,500 m or above. Ask the compressor manufacturer for the derating table for your model and elevation, and size on the derated output rather than the nameplate figure.

What happens if the compressor is too small?

The drill loses impact energy and the penetration rate falls, so the hole takes longer and the bit wears faster for the same metre drilled. Persistent underfeeding also shortens the life of the percussion mechanism, which is why an undersized compressor is usually more expensive than the right one.

Tell us what you are drilling

Send the rock type, the hole diameter and depth you need, and the compressor you already have or plan to buy. Our engineering team will come back with the drill combination that fits the air you have, and the published figures behind it.

Request a technical assessment