How to Size a Pneumatic Motor and Gear Reducer
An air motor is almost never specified on its own. What a machine actually needs is a torque at a speed, and a pneumatic motor on its own runs too fast and too light to deliver it. The reducer is what converts the motor’s speed into the torque your mixer, winch, hoist or conveyor is asking for. This guide sets out how to size the pair together, using the published ratings of our reducers, and explains the one specification that is most often misread.
Key takeaways
- Specify the driven machine first: the torque it needs at its shaft, and the speed that shaft must turn.
- Output torque comes from the motor torque multiplied by the reducer ratio, less the losses in the gear mesh. Output speed is the motor speed divided by the ratio.
- Published reducer ratings: ZR10 25:1 at 560 Nm, ZR50 40:1 at 340 Nm, ZR80 84:1 at 370 Nm, RR10-1000 planetary at 24:1.
- Every reducer in the range accepts a maximum input speed of 3,000 rpm. That is a hard limit, not a guideline.
- Nominal power and thermal power are different numbers. Thermal power is what governs continuous duty, and ignoring it is the most common cause of a reducer running hot.
- An air motor stalls under overload without damage and restarts when the load clears, which is why it survives duties that burn out electric drives.
1. Start at the driven shaft
The sizing conversation almost always begins in the wrong place, with a question about motor power in kilowatts. Power alone cannot size a drive, because the same power can be delivered as high speed with little torque or low speed with a great deal of it, and your machine only accepts one of those.
So begin with two numbers about the machine you are driving. What torque does its shaft need, in newton metres, including the worst moment rather than the average? And what speed must that shaft turn, in rpm? If you do not know the torque, the load usually tells us: the diameter of a mixer paddle and the material it stirs, the drum diameter and the mass a winch lifts, the belt width and the tonnes per hour on a conveyor. Send the load and we can work backwards to the torque.
2. Why an air motor is specified differently from an electric one
Three behaviours separate a pneumatic motor from an electric motor, and all three affect how you size it.
It stalls without harm. Load an air motor past its capacity and it simply stops turning; release the load and it starts again. There is no winding to burn, no overload relay to reset, no thermal trip. For a mixer that occasionally sets hard, or a winch that snags, this behaviour is the reason the drive is pneumatic in the first place.
Its speed falls as the load rises. An air motor does not hold a constant speed the way a mains electric motor does. As resistance increases, it slows and its torque rises. That makes it forgiving in variable duty, but it also means you size for the torque at the speed you actually need, not for a single nameplate figure.
It tolerates conditions that stop other drives. Our vane type and axial piston motors are built for dust, moisture and temperature swings, and support continuous start-stop cycles and direction changes without overheating. They generate no heat of their own, carry no electrical parts, produce no sparks and use no hydraulic fluid, so there is nothing to leak and nothing to ignite. Where that matters formally, both are available in ATEX versions; which variant you need is a separate decision we cover in ATEX pneumatic motors for hazardous environments.
Which of the two architectures suits your duty — vane for smooth running and a high speed range, axial piston for high torque at low speed — is covered in vane versus axial piston pneumatic motors.
3. The reducer does the heavy lifting
These are the published ratings of the reducers we build in Ankara to pair with our motors.
| Model | Type | Ratio | Nominal torque | Nominal power | Thermal power | Stages | Shaft | Weight |
|---|---|---|---|---|---|---|---|---|
| ZR10 | Worm | 25:1 | 560 Nm | 4–5.5 kW | 0.4 kW | 1 | 90° | 5.5 kg |
| ZR50 | Worm | 40:1 | 340 Nm | 1.5–2.2 kW | 0.3 kW | 1 | 90° | 6.5 kg |
| ZR80 | Parallel shaft | 84:1 | 370 Nm | 0.75–1.1 kW | 2.2 kW | 3 | Parallel, offset | 8.5 kg |
| RR10-1000 | Planetary | 24:1 | — | — | — | — | 180° operating angle | — |
Read that table as a set of trade-offs rather than a ladder. The ZR10 carries the most torque of the three worm and parallel units at a moderate ratio. The ZR50 gives a higher ratio and therefore a lower output speed, but it is rated for less torque. The ZR80 reaches 84:1 through three stages, which is the model to choose when a machine needs genuinely slow, steady rotation — feeds, slow conveyors, positioning drives.
Maximum input speed is 3,000 rpm on every unit in the table. If a motor can turn faster than that unloaded, the drive has to be arranged so the reducer never sees more.
4. Nominal power and thermal power are not the same number
This is the specification that gets skipped, and it is the one that explains most reducers that run too hot.
Nominal power is the mechanical power the reducer is rated to transmit. Thermal power is the continuous power it can shed as heat without overheating. They are independent, and the lower of the two governs continuous duty.
The ZR10 makes the point plainly: 4–5.5 kW nominal, but 0.4 kW thermal. It will transmit the higher figure in intermittent service — a winch that lifts and stops, a gate that opens twice a shift — but a duty that runs hour after hour has to respect the thermal figure or find a way to cool the unit. The ZR80 is the opposite shape: 0.75–1.1 kW nominal against 2.2 kW thermal, which is a unit comfortable running continuously at its rating.
So the question “will this reducer handle my load” has two answers depending on whether the duty is intermittent or continuous, and you need to tell us which.
5. A worked example
Take a mixer that needs roughly 450 Nm at its shaft, turning slowly, in a plant where an electric drive is unwelcome.
Drive: EP80 axial piston motor with a ZR10 worm reducer at 25:1.
Result: about 450 Nm at about 44 rpm at the output shaft.
Check 1 — torque: 450 Nm sits inside the ZR10’s 560 Nm nominal rating, with margin.
Check 2 — input speed: 44 rpm out at 25:1 means about 1,100 rpm in, comfortably under the 3,000 rpm limit.
Check 3 — duty: if that mixer runs continuously, the 0.4 kW thermal rating is the binding constraint and the drive needs reviewing; if it runs in batches, it is fine.
Notice that the third check is the one that changes the answer, and it has nothing to do with torque. Two plants asking for the same 450 Nm can need different drives because one runs in batches and the other runs all shift.
6. Choosing the reducer type by the space you have
Ratio and torque narrow the choice; the geometry of the machine usually finalises it.
A worm reducer turns the drive through 90°, so the motor sits alongside the machine instead of in line with it. On a conveyor or a winch where length is scarce, that is often the deciding factor, and the worm-and-wheel mesh runs quietly while giving a high ratio in one stage.
A parallel shaft unit keeps the output parallel to the input but offset, in a flat housing that bolts on. It suits installations where the drive has to sit close against a frame.
A planetary unit puts the output in line with the input and distributes load across several gears, which gives even load sharing and low vibration in a compact body. The RR10-1000 at 24:1 is configured for a 180° operating angle, which suits applications needing controlled directional movement.
The rule in one line. Torque and speed at the driven shaft choose the ratio; the torque rating confirms the reducer; the thermal rating decides whether it survives your duty cycle; the geometry of the machine picks the type.
7. What to send us
Five things let our engineering team specify the pair without a round of questions: the machine being driven, the torque it needs at its shaft or the load from which we can calculate it, the required output speed, whether the duty is intermittent or continuous, and whether the area requires an ATEX-certified motor. Add the available air supply if you know it, and the space the drive has to fit into.
If you are replacing a drive that keeps failing, tell us what failed and how. A reducer that runs hot points at thermal rating; a motor that stalls repeatedly points at torque; a drive that wears out bearings usually points at the mounting rather than the rating.
Multiply the motor’s torque by the reducer ratio and subtract the losses in the gear mesh. Output speed is the motor speed divided by the ratio. For example, an EP80 axial piston motor with a ZR10 worm reducer at 25:1 delivers about 450 Nm at about 44 rpm.
Nominal power is the mechanical power the reducer can transmit. Thermal power is the power it can continuously dissipate as heat without overheating. For continuous duty the lower figure governs. The ZR10 is rated 4 to 5.5 kW nominal but 0.4 kW thermal, so a continuously running load must respect the thermal figure.
Divide the motor speed by the output speed your machine needs. Published ratios are 24:1 on the RR10-1000 planetary, 25:1 on the ZR10 worm, 40:1 on the ZR50 worm and 84:1 on the ZR80 parallel shaft. Then confirm the chosen unit’s torque rating covers your load.
All models in the range accept a maximum input speed of 3,000 rpm. If the motor can exceed that when unloaded, the drive must be arranged so the reducer never receives more than 3,000 rpm at its input.
It stalls and stops turning, and starts again once the load is released. There is no winding to burn out and no overload device to reset. This tolerance of stalling is a principal reason for choosing an air drive on machines that jam or set hard.
A worm reducer turns the drive through 90 degrees, which saves length on conveyors and winches. A parallel shaft unit keeps the output parallel but offset in a flat bolt-on housing. A planetary unit is in line and compact, sharing load across several gears for low vibration. Ratio and torque narrow the choice; the space in the machine usually settles it.
Send us the load, not the motor
Tell us what the machine is, the torque and speed its shaft needs, whether it runs in batches or continuously, and whether the area is classified. Our engineering team will specify the motor and reducer pair and show the figures behind the choice.
Request a technical assessment