This page is not for quarry operators. It is for people who build machines and need a drive to put inside one, and for people who keep a plant running and have a drive that keeps failing.

We make pneumatic motors and gear reducers in Ankara and have done since 1991. They turn shotcrete rotor drums, galvanizing baskets, winches, pumps, conveyors, agitators and fans — some supplied in series to companies that build those machines, some fitted as replacements in plants that had an electric motor in the wrong place. This page is about choosing a drive by what it has to turn.

The short version, if you are only here for a minute

  • Two motor families — vane for speed and compactness, axial piston (the EP series) for torque and loaded starts — each in three versions: underground ATEX, surface ATEX, and standard.
  • Three reducers: worm for a right-angle output, parallel shaft to stay in line, planetary for controlled motion.
  • Specify by the load the drive has to hold, not the load it has to turn. Start from the driven machine and the duty cycle, never from the nameplate of the motor you are replacing.
  • Air motors earn their place where an electric motor cannot go: no spark, no electronics to drown, and a stall that stops instead of burning out. The honest trade-off is that compressed air costs more per unit of work.
  • What we do not do: no electric or hydraulic motors, no drives or controls, no cylinders or valves, no compressors, and we do not design your machine.

Why put an air motor where an electric motor would go?

Four reasons, and none of them is preference. An air drive produces no heat, no electricity and no spark, so it can work in an atmosphere an electric motor cannot enter. It stalls instead of burning out. It tolerates continuous stop-start and reversal without overheating. And it shrugs off dust, humidity and temperature swings.

Put another way, each reason maps onto a specific failure an electric drive has already caused somewhere:

  • Ignition risk in vapour, dust or gas. No electrical supply at the drive means nothing to ignite it with. There is no hydraulic fluid either, so no leak and no fire load.
  • Burn-out under overload. Immerse a heavy load and an electric motor locks and cooks. An air motor stalls, then picks up again when the load releases. The difference is a ten-minute stoppage against a motor change.
  • Duty cycles that never settle. A basket going up and down all shift, a drum starting under load every few minutes — cycling and reversal are what air motors are good at.
  • Ambient conditions. Wash-down, abrasive dust, chemical vapour, heat. These are what kill electrical equipment first, and an air motor is largely indifferent to them.

Where a zone classification applies, our motors come in three certification versions and choosing the wrong one has legal as well as practical consequences. That is a subject in its own right, so we have written it up separately rather than summarising it here: ATEX pneumatic motors — underground, surface and normal use.

Vane type pneumatic motor in its ATEX version for industrial drives

And the cost, which we are not going to hide. Compressed air is expensive to produce, so an air drive consumes more primary energy than an electric motor of equivalent output. It also needs a network in good order — dry air, line lubrication, correctly sized pipe runs. If your machine works indoors, at steady load, with no atmosphere or wash-down problem, an electric motor is probably the right answer and we will tell you so.

Which driven machine are you trying to turn?

This is the useful question, and it is the one we start from. Find the thing that has to rotate in the left-hand column — the drive follows from its duty, not from a catalogue page.

What has to turnWhy air suits itWhat we ask you first
Rotor drum on a shotcrete machineStarts under load every cycle, works underground where a zone classification appliesDrum breakaway torque, cycle rate, and the zone the machine is sold into
Dipping basket or centrifugal cage in a molten bathHeat, chemical vapour and repeated overload as parts go in; stalling beats burning outLoaded basket weight, bath temperature at the drive, and how fast direction has to reverse
Mixer or agitatorHigh breakaway torque from standstill in a thickened medium, then low steady speedStarting torque against running torque, and whether it must restart into a set load
Dewatering pumpWet, often in a sump, no electrical supply wanted near standing waterHead, flow and whether the drive runs submerged or alongside
Winch or hoistLoad held as well as lifted, and controllable creep speed in both directionsLine pull, drum diameter and what holds the load when the air is shut off
Conveyor or feederDust and wash-down, frequent starting against a full beltBelt load at start, required speed range, and the reducer ratio that gets you there
Fan or blowerVentilation in places where electrical equipment is restrictedShaft power at duty point and the speed range you need to trim

The specification error we see most. Someone reads the kilowatt rating off the electric motor being replaced and asks for an air motor of the same number. It does not transfer. An air drive is sized from the load it has to hold and the torque it has to produce at the speed you actually run, and a reducer usually does more for you than a bigger motor would. Send the driven machine, not the old nameplate.

Where the numbers are

We are not going to restate a specification table here that already exists properly elsewhere. All seven motors are published side by side with their power, speed, torque, stall torque, air consumption and weight at 6 bar, plus the three certification versions and the three reducers, on the category page.

SET MAKINA pneumatic motor performance data

Motors and reducers — the full comparison
Seven motors, three reducers, three certification versions, all figures measured at 6 bar with a 5 to 7 bar working range. Start here if you want to read the numbers yourself.

ATEX certified pneumatic motor for hazardous area drives

Vane against axial piston
Which architecture suits which drive, and why the answer is usually about torque at low speed rather than about power. Written up in full rather than compressed into a bullet here.

Gear reducer for an industrial pneumatic drive

The reducer does the heavy lifting
A motor sets the speed; the reducer turns it into usable force. Worm for a right-angle output, parallel shaft to stay in line, planetary for controlled motion. Ratios and models are on the category page.

There are also printed catalogues for the vane and EP ranges with more detail than we put on the web. Ask and we will send the relevant one — no form, no gate.

Two plants, and what the drive had to solve

Both are written up in full elsewhere rather than retold here. Neither publishes a measured figure, because we did not take one.

A machine builder, not an end user

A manufacturer of shotcrete machines for underground work needed a drive that would hold rotor-drum rotation continuously and let it ship machines with the certification its own customers demanded. The vane motor on the previous version did not have the power for the application, and it had no ATEX certification.

The answer was an EP piston motor in its ATEX version — a change of architecture, from a motor sized for speed to one sized for torque at a loaded start. A larger EP model is on trial for the bigger machines in the same range; we publish no result for that, because the trial is not finished.

Read the case study

A plant, where the drive sits over a bath

Hot-dip galvanizing: basket dipping machines and rotating bath systems working over molten zinc. Three problems at once — ignition risk from high temperature and chemical vapour, overload every time a heavy load goes into the bath, and an ambient environment that destroys electrical equipment.

The EP series answered all three for the same reason: no electrical supply at the drive, enough torque to keep a loaded basket turning under the bath, and a stall that stops rather than burns. Rapid reversals for dipping and lifting come as part of how the motor works, not as a feature.

Read the case study

A third plant story sits slightly outside this page but is worth knowing if you run a batching plant: removing hardened concrete from mixer and truck drums — a pneumatic breaker rather than a drive, but the same plant and the same maintenance crew.

What we supply, and what we leave to you

What we supply

  • Vane pneumatic motors, in standard and ATEX versions
  • Axial piston pneumatic motors — the EP series — in standard and ATEX versions
  • Worm, parallel shaft and planetary gear reducers
  • The motor-and-reducer package sized against your driven machine
  • The air flow and pressure your installation will need
  • Technical catalogues on request
  • Series supply to a machine builder, over the life of a product

What we do not supply

  • No shotcrete machines and no galvanizing machines. We supply the drive to some of the companies that build them
  • No electric or hydraulic motors
  • No variable speed drives, PLCs or control panels
  • No cylinders, actuators or valves as standalone products, and no general pneumatic fittings business — we make motors and reducers
  • No compressors, dryers or turnkey air networks — we size the demand, the installation is yours
  • No hand-held air tools as an industrial tooling range
  • We do not design your machine. We size the drive inside it; the rest is yours

Questions we get asked

Can I just replace my electric motor with the same kilowatt rating in air?

No, and this is the most common way a drive ends up undersized. Work from the load: the breakaway torque, the running torque at the speed you actually use, the duty cycle. Then pick the motor and the reducer together. Send us the driven machine and we will do that calculation.

Will you supply in series for a machine we build?

Yes — both of our documented applications are exactly that. Tell us your build rate and the horizon over which you need the same part number available, and we will have that conversation properly rather than putting a promise on a web page.

Does the motor come with the reducer?

The reducer is an option, chosen from the speed and torque you need at the output. Three types are available: worm for a right-angle output, parallel shaft to stay in the axis, planetary for controlled motion.

My plant has a zone classification. Which version do I need?

There are three versions — underground ATEX, surface ATEX and standard — and they are not interchangeable. We do not extend one model’s certification to another. Send us the zone classification from your own documentation and we will confirm in writing which version applies.

What does the installation need beyond the motor?

Clean dry air at working pressure, and an inlet filter and lubricator. Those two are not accessories — running a motor without them voids the warranty. We will give you the flow figure for your duty so the network can be checked before anything is ordered.

How long do they last, and what wears out?

On a vane motor the vanes are the wear part and have a published replacement interval; the category page carries it. Beyond that, service life depends on your duty cycle and your air quality far more than on the motor, which is why we ask about both before quoting.

Where are they made?

Ankara. The vane motor’s own product page puts it plainly — manufactured one hundred per cent by SET-A Makina, with CNC machining and quality control in house. Parts and technical answers come from the workshop that built it.

Tell us what it has to turn

The driven machine, the torque it needs to break away from standstill, the speed you run it at, the cycle, and the zone if there is one. We come back with a motor, a reducer and the air flow it will draw — and with the catalogue, so you can check our work. If an electric drive is the better answer for your case, we will say so.

Case Studies

Removing Hardened Concrete from Mixers and Truck Drums with the TIGER 8 BREAKER

Ready-mix concrete producers clean set concrete from plant mixers and truck drums with a light pneumatic breaker.

pneumatic motor for galvanizing basket

Pneumatic Solutions for Hot-Dip Galvanizing Plants

ATEX-safe operation for hot-dip galvanizing environments with high vapor exposure.

USE OF EP PNEUMATIC MOTORS AND GEARBOXES PRODUCED BY SET MAKINA

A manufacturer of shotcrete machines for underground applications sought to deliver consistent and safe performance in its equipment.